![]() |
Brand Name: | JIWEI |
Model Number: | JW-QSM11 |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | ,T/T |
Application field
● Industrial field: factories, mines, construction sites, etc., can ensure the continued operation of production equipment in the event of power failure to avoid production interruption caused by losses.
● Commercial field: shopping malls, hotels, office buildings and other places can supply power to lighting, air conditioning, elevators and other equipment when the mains fails to ensure normal business.
● Medical field: hospital operating rooms, intensive care units, medical equipment, etc., have high requirements for power, Cummins diesel generator sets can be used as backup power to ensure the safety of patients.
● Data center: Provide stable power for servers, network equipment, etc., to prevent data loss and business interruption.
GENERATING SET DATA | ||||
Relatedrange of voltage setting | ≥±5% | |||
Steady-state voltage deviation | ≤±1% | |||
Transient voltage deviation(100 %suddenpowerdecrease) |
≤+25% | |||
Transient voltage deviation (suddenpowerincrease) |
≤-20% | |||
Voltagerecovery time(100 %suddenpowerdecrease) |
≤6S | |||
Voltagerecovery time (suddenpower increase) | ≤6S | |||
Related range of frequency setting | 0-5%adjustable | |||
Steady-state frequency band | ≤1.5% | |||
Transient frequency deviation (100 %suddenpowerdecrease) |
≤+12% | |||
Transient frequency deviation (suddenpowerincrease) |
≤-10% | |||
Frequencyrecovery time (100 %suddenpowerdecrease) |
≤5S | |||
Frequencyrecovery time (suddenpower increase) | ≤5S | |||
STANDARDFEATURES | ||||
Standard auto controlsystem | Exhaust system (includinguntilmuffler) |
Documents | ||
Oil drainvalve | Startingbatteries (maintenance-free &watering -free)with connective wires |
Special tools | ||
MCCB |
![]() |
Brand Name: | JIWEI |
Model Number: | JW-QSM11 |
MOQ: | 1 |
Price: | Negotiable |
Payment Terms: | ,T/T |
Application field
● Industrial field: factories, mines, construction sites, etc., can ensure the continued operation of production equipment in the event of power failure to avoid production interruption caused by losses.
● Commercial field: shopping malls, hotels, office buildings and other places can supply power to lighting, air conditioning, elevators and other equipment when the mains fails to ensure normal business.
● Medical field: hospital operating rooms, intensive care units, medical equipment, etc., have high requirements for power, Cummins diesel generator sets can be used as backup power to ensure the safety of patients.
● Data center: Provide stable power for servers, network equipment, etc., to prevent data loss and business interruption.
GENERATING SET DATA | ||||
Relatedrange of voltage setting | ≥±5% | |||
Steady-state voltage deviation | ≤±1% | |||
Transient voltage deviation(100 %suddenpowerdecrease) |
≤+25% | |||
Transient voltage deviation (suddenpowerincrease) |
≤-20% | |||
Voltagerecovery time(100 %suddenpowerdecrease) |
≤6S | |||
Voltagerecovery time (suddenpower increase) | ≤6S | |||
Related range of frequency setting | 0-5%adjustable | |||
Steady-state frequency band | ≤1.5% | |||
Transient frequency deviation (100 %suddenpowerdecrease) |
≤+12% | |||
Transient frequency deviation (suddenpowerincrease) |
≤-10% | |||
Frequencyrecovery time (100 %suddenpowerdecrease) |
≤5S | |||
Frequencyrecovery time (suddenpower increase) | ≤5S | |||
STANDARDFEATURES | ||||
Standard auto controlsystem | Exhaust system (includinguntilmuffler) |
Documents | ||
Oil drainvalve | Startingbatteries (maintenance-free &watering -free)with connective wires |
Special tools | ||
MCCB |